    Details description

    Measurement principle Ultrasound


    Features/Applications

    Compact Ultrasonic Transmitter 

    Power/Communication

    Two-wire connection 

    Measurement accuracy

    +/- 3mm or +/- 0.2% of the set range 

    Environmental temperature

    -20... 60 °C

    (-4...) 140 °F)


    Process temperature

    -20... 60 °C

    (- 4... 140 °F)


    Process pressure (absolute pressure) / Maximum overpressure limit value

    0.7... 3 bar abs

    (10...) 44 psi)


    Main liquid-receiving components PP/EPDM


    Process connection G / NPT 1 1/2"

    G / NPT 2"


    Blind zone distance

    1 1/2": 0.25 m (0.8 ft)

    2": 0.35 m (1.15 ft) 

    Application

    Application


    Maximum measurement distance Sensor 1-1/5": 5 m (16 ft)

    Sensor 2": 8 m (26 ft)


    Communication

    4... 20mA


    Certificates and certifications

    ATEX, CSA C/US, IEC Ex, NEPSI 

    Options

    Installation accessories:

    UNI flange 2" ... 4"


    Application Restrictions For higher resistance:

    FMU41/42/FDU9x

    Foam / high turbulence possible:

    FMU42/FDU91

    Fast filling and discharging rate:

    FMU90 + FDU9x

    Level limit detection:

    FMU90 + FDU9x